OPERATING INSTRUCTIONS
SETTING THE TIME AND DAY:
Open the door on the front of the thermostat. Rotate the dial to the
SET DAY/TIME position. You should see the display pictured below with a day of
the week flashing.
HARDWARE RESET
This button will read option jumper positions, before the unit begins normal
operation. It is located inside on the rear of the unit’s circuit board. It is a small
square component with a white button at it’s center. Pressing Hardware Reset will
allow the unit to read the new jumper settings without losing your program.
●
Press UP to change day of week.
●
Press NEXT to set the time;it will flash.
●
Press UP or DOWN to change time of
day.
When you are finished setting the day and time, rotate the dial to RUN to return to
normal operation or to another position to continue programming.
MORN
DAY
EVE
NIGHT
AM
MO TU WE TH FR
The PSP511A/PSP511LA alternately displays the current time and the room
temperature, and the day of the week. The current program period, MORN, DAY,
EVE or NITE is indicated by an arrow at the left edge of the screen. Set tempera-
tures are indicated in the right side of the display.
With batteries installed, you can make program or setting changes with the
thermostat body on the wall, or conveniently removed from its base plate.
FAN MODES:
The fan switch has two positions; AUTO will automatically run your system’s
fan as required for heating and cooling only. ON runs your system’s fan continu-
ously.
NOTE
The FAN switch works only if your system provides a wire for the
PSP511A/PSP511LA’s “G” terminal.
CHANGING TEMPERATURE AND OTHER SETTINGS:
If there are many choices for a value, usually that setting will automatically
advance by holding the Up or Down key. Some settings though, must be changed
one press at a time.
DISPLAY ILLUMINATION:
Press any key to illuminate (PSP511LA only) the display. Pressing any key will
keep the display illuminated until no button has been pressed for approximately
20 seconds.
TEMPERATURE CONTROL MODES:
The Mode switch has three positions HEAT, OFF, and COOL. In the winter, set
the system switch to HEAT to control your heating system. In the summer, set the
switch to COOL to control your air conditioner. In spring and fall or when the win-
dows are open, you can set the switch OFF.
UP/DOWN/CHANGE KEYS:
UP/DOWN keys are just right of the unit’s display. They are used to adjust set
temperatures and change other settings.
SOFTWARE RESET
Use this front panel RESET to return all software settings and programs to their
default values. Option jumpers will be read and operation will correspond to their
current positions. To assist in reprogramming, copy your programs into the chart
provided before using SOFTWARE RESET.
PROGRAMMING CHART
DAY
PERIOD HEAT COOL
TIME TEMP. TIME TEMP.
MON.
MORN
THRU
DAY
FRI.
EVE
NIGHT
MORN
SAT.
DAY
and
EVE
SUN.
NIGHT
PROGRAMMING
The PSP511A/PSP511LA provides two separate programs, one for heating the
other for cooling. Each program has separate settings for weekdays and week-
ends. Every day a program cycles through four independent periods. You can use
the default programs or alter them to suit your schedule.
DEFAULT ENERGY STAR
®
TEMPERATURE PROGRAM
As supplied from the factory, the following ENERGY STAR
®
approved program
will be used for temperature control in RUN mode. This program and all other
software settings may be restored to their default values via a SOFTWARE RESET.
WEEKDAY PROGRAMMING
1. Select HEAT or COOL with the mode switch.
2. Rotate dial to SET WEEKDAY PROGRAMS.
You will see the display shown here:
WEEKEND PROGRAMMING
1. To review or change the weekend program,
select HEAT or COOL and rotate the dial to SET
WEEKEND PROGRAMS. You will see a display
similar to that shown here:
2. Use steps 4 - 10 described in WEEKDAY
PROGRAMMING to program Saturday and Sunday.
MORN
DAY
EVE
NIGHT
AM
SA SU
600
70
EDITING HEAT OR COOL PROGRAMS
You can review or change any preset times and/or temperatures to suit your
schedule for each day of the week. The four periods each day are
Morning(MORN), Day,(DAY) Evening(EVE), and Night(NITE).
MORN
DAY
EVE
NIGHT
AM
MO TU WE TH FR
600
70
Morning
Day
Evening
Night
6:00 AM 70°F (21°C)
8:00 AM 62°F (17°C)
6:00 PM 70°F (21°C)
10:00 PM 62°F (17°C)
6:00 AM 78°F (26°C)
8:00 AM 85°F (29°C)
6:00 PM 78°F (26°C)
10:00 PM 82°F (28°C)
PERIOD HEAT MODE COOL MODE
TEMPERATURE OVERRIDE
OVERRIDE allows you to change the current SET TEMPERATURE in HEAT or
COOL until the next program period without changing your temperature control
programs.
●
Press an arrow key once.
●
While the Set Temperature is flash-
ing; press an UP or DOWN key to
adjust the set temperature by one
degree in the associated direction.
Holding the key will automatically advance the setting in the associated direction.
●
The OVERRIDE will be canceled at the start of the next program period, and the
temperature setting will return to its programmed value.
●
An OVERRIDE may be terminated by rotating the dial, switching the mode to OFF,
or initiating a HOLD.
●
Adjusting the set temperature to
its program value will also cancel an
OVERRIDE.
TEMPERATURE HOLD
HOLD may be used for manual
temperature control. HOLD is the
simplest means to set and maintain a fixed temperature. It allows you to set and
maintain a temperature Set Point indefinitely in Heat or Cool without concern for
programming. To initiate a HOLD:
●
Press and release HOLD.
●
After the Set Temperature begins to flash, adjust temperature as desired with UP or
DOWN keys.
●
Temperature setting will not change until the HOLD is cancelled.
●
To cancel a HOLD, press and release HOLD again, rotate the dial, or switch mode
to OFF.
3. All 5 weekday abbreviations will be displayed indicating that this program will
cycle once each of these days,
4. The HEAT or COOL set temperature will be displayed on the right side of the dis-
play. The start time for the displayed period will flash to show that this may be
changed.
5. Use the Up and Down keys. One period ends at the start time of the next period.
The beginning of that period may not be any closer to the beginning of the next peri-
od than one 15 minute increment.
6. Press NEXT to accept the displayed start time and advance to edit the SET TEM-
PERATURE.
7. Use the UP and Down keys to change the flashing HEAT or COOL set tempera-
ture to the temperature you desire.
8. Press NEXT to accept the displayed set temperature and advance to edit the
start time for the next period. It will be flashing.
9. Repeat for each of the four periods. When all the periods for the weekday pro-
gram have been set, the start time for the morning will again be displayed flashing so
that it may be edited.
10. Rotate the dial back to RUN to accept all current values and end the weekday
programming session.
MORN
OVERRIDE
DAY
EVE
NIGHT
70
730
MO TU WE TH FR
MORN
HOLD
DAY
EVE
NIGHT
65
730
MO TU WE TH FR
DOWN
UP
HOLD